BACKGROUND

The American Association of Critical-Care Nurses practice alert on verification of feeding tube placement makes evidence-based practice recommendations to guide nursing management of adult patients with blindly inserted feeding tubes. Many bedside verification methods do not allow detection of improper positioning of a feeding tube within the gastrointestinal tract, thereby increasing aspiration risk.

OBJECTIVES

To determine how the expected practices from the American Association of Critical-Care Nurses practice alert were implemented by critical care nurses.

METHODS

This study was part of a larger national, online survey that was completed by 370 critical care nurses. Descriptive statistics were used to analyze the data.

RESULTS

Seventy-eight percent of nurses used a variety of methods to verify initial placement of feeding tubes, although 14% were unaware that tube position should be confirmed every 4 hours. Despite the inaccuracy of auscultation methods, only 12% of nurses avoided this practice all of the time.

CONCLUSIONS

Implementation of expected clinical practices from this guideline varied. Nurses are encouraged to implement expected practices from this evidence-based, peer reviewed practice alert to minimize risk for patient harm.

The findings presented here are a subset of results from a larger study that examined critical care nurses’ adoption of the American Association of Critical-Care Nurses (AACN) practice alert on feeding tube placement and the clinical practices recommended therein.1  Insertion of feeding tubes to deliver enteral nutrition is a common intervention in critically ill patients; however, the methods used for feeding tube verification and the frequency of their use vary widely.2  Two verification methods that are not supported by research evidence, auscultation (air bolus)2  and water bubbling (no published evidence found), continue to be used. Unfortunately, adverse outcomes such as pneumonia, pneumothorax, and death have been associated with inconsistent practices for verifying feeding tube placement.35  The most common complication of blindly inserted feeding tubes is improper placement in the esophagus (21% of cases) or pulmonary system (4% of cases).3,6  Case studies7,8  of feeding tubes placed in the brain and spinal column also have been published. Incorrect placement of a feeding tube may be difficult for clinicians to assess at the bedside, because the patient can be asymptomatic initially.9,10  Because of this, radiographic confirmation is considered the gold standard for initial verification of placement of all blindly inserted feeding tubes.1114 

Clinical practice guidelines such as the AACN practice alerts contain recommendations for practice that are evidence-based.15  Guidelines synthesize available evidence to assist clinicians in translating research findings into clinical practice.16  AACN’s practice alert on verification of feeding tube placement was originally published in 2005, revised in 2009, and is available on the AACN website (www.aacn.org).17  Several clinical practice guidelines supporting practices for verifying feeding tube placement have been published by other organizations, including the American Association of Parenteral and Enteral Nutrition, the American Gastroenterological Association, and England’s National Health Service.11,12,14 

Previously published data from our larger study examined the influence of Rogers’ diffusion of innovation variables on critical care nurses’ adoption of the AACN practice alert on feeding tube placement and its recommended clinical practices in adult patients with feeding tubes.1  The term adoption is commonly used to describe the processes of accepting and implementing an innovation such as the AACN practice alert.18 Implementation is a term commonly used in nursing practice and refers to the action of using an innovation. For the purpose of this article, the terms adoption and implementation will be used in reference to the use of a clinical practice unless otherwise stated.

Whereas our first article1  reported on factors that increased the likelihood of adoption of the practice alert, this article explores how the recommendations in the AACN practice alert were used by critical care nurses to verify feeding tube placement in clinical practice. No unique findings regarding radiographic confirmation are reported here.

The AACN practice alert on verification of feeding tube placement for blindly inserted tubes contains 3 major recommendations under the heading Expected Practice17  (Table 1). The practice alert identifies the unreliable auscultatory (air bolus) method as a subset of the first recommendation. Because auscultation is reported as a method commonly used by nurses to verify feeding tube location, we decided to measure auscultation practice separately from the 3 major practices recommended in the practice alert.

Design

This study had a cross-sectional, exploratory design that used survey methods. The online survey was hosted by the University of Georgia Survey Research Center. Study approval was provided by the institutional review board at Georgia Health Sciences University (now Georgia Regents University), and data collection occurred during September and October 2011.

Instrument

The survey tool consisted of 86 categorical and Likert-style questions that measured adoption of the AACN practice alert, adoption of the practice alert’s recommended clinical practices, perceived guideline characteristics, personal innovativeness, communication behaviors, and collaboration. Only data from the Nursing Practice Questionnaire (NPQ),19  a subscale that measured clinical practices related to the practice alert, are reported here. NPQ items received minor customization to capture recommended practices from the practice alert. Our NPQ scale had an internal reliability coefficient (Cronbach a) of 0.82. The NPQ consisted of 8 items for each individual practice and required mostly yes/no categorical answers. Respondents were asked to indicate whether they use a practice: yes, sometimes; yes, always; no, not aware of practice; or no, aware of practice. No definition was provided for performing a practice “yes, sometimes,” and thus selection of a response was left to the interpretation of the participant.

For questions about specific verification methods, only methods recommended by the practice alert were included as survey options. Therefore, auscultation and water bubbling methods were not included as survey options because these methods are not empirically based. All items were related to the care of blindly inserted nasogastric or feeding tubes. A blindly inserted tube was defined as a feeding tube that is inserted without imaging guidance such as fluoroscopy, endoscopy, or sonography. No distinction was made between small-bore (styleted) and large-bore (nonstyleted) feeding tubes.

Original wording in the practice alert under the heading of Expected Practice states “Obtain radiographic confirmation …” Radiographic confirmation is not an independent practice for generalist nurses, so we revised the language in our survey and asked if nurses recommend/encourage radiographic confirmation. Survey questions were reviewed by expert nurses for face validity, and a pilot test of the online survey was performed by 27 AACN members.

Recruitment

Invitations to participate were included in AACN’s Critical Care Newsline for 4 consecutive weeks. Detailed recruitment methods have been described previously.1 

Sample

Descriptive statistics were used to present demographics and clinical practice data. The final sample consisted of 370 critical care nurses (Table 2). A complete description of the sample was previously published.1  Participants were 23 to 65 years old (mean, 43 years) and had 1 to 40 years (mean, 13 years) of critical care nursing experience. About 83% were AACN members, 51% were CCRN certified, and 14% worked in a Beacon unit. Baccalaureate or higher nursing degrees were held by 74% of the nurses.

Initial feeding tube placement should be verified by using multiple methods.

Use a Variety of Methods To Predict Initial Location of Feeding Tube

Seventy-eight percent of participants (n=287) used a variety of methods to verify initial feeding tube placement all of the time, and 12% (n=45) implemented this practice only some of the time. Ten percent of nurses (n=38) were unaware of this practice recommendation. A total of 332 respondents answered the question about the specific methods that were used to verify tube placement. Verification methods reported to be used all of the time included observing for signs of respiratory distress (95%, n=315/332), observing feeding tube aspirate (82%, n=272/332), and marking the feeding tube at the exit site (72%, n=239/332; Figure 1). Capnography and pH measures were used less frequently (8%, n=26/332 and 9%, n=30/332, respectively). In the open comment field, participants identified the use of 2 additional methods for verification of initial tube placement: auscultation (20%, n=67/332) and the water bubbling technique (0.6%, n=2/332).

Check Feeding Tube Location at 4-Hour Intervals

Fourteen percent (n=50) of nurses were unaware that feeding tube location should be reassessed every 4 hours. A total of 309 respondents answered questions about the specific methods they used to reassess tube position at 4-hour intervals. Methods always used included observing change in aspirate volume (89%, n=276/309), observing the appearance of feeding tube aspirate (81%, n=251/309), observing change in external length of the feeding tube (80%, n=248/309), obtaining a radiograph (66%, n = 203/309), reviewing the radiography report (52%, n=162/309), and pH measurement (7%, n=21/309; Figure 2). Five percent (n = 16/309) of nurses reported in an open comment field that they also used auscultation for ongoing verification of feeding tube location.

Avoid Auscultatory (Air Bolus) Method

Twelve percent (n=46) of participants indicated that they avoided using the auscultatory (air bolus) method all of the time. Ten percent (n=38) avoided auscultation some of the time, and 77% (n=286) never avoided using the auscultatory (air bolus) method to verify feeding tube location (Figure 3). Forty percent of nurses (n=149) were unaware that the auscultatory method is considered unreliable.

Fifty-five percent of participants (n=203) were aware of the practice alert, yet only 45% (n=167) indicated that they had used the practice alert when caring for a patient receiving enteral feeding.1  The methods used by nurses with CCRN certification or who were employed in a unit with Beacon award status did not differ from the methods used by other nurses. CCRN is an acute/critical care specialty certification through AACN.20  The Beacon award for excellence is presented by AACN to units that meet rigorous criteria related to patients’ outcomes and work environment.21 

The main goal when inserting feeding tubes blindly is to place the tube within the gastrointestinal tract, in either the stomach or the small bowel, and avoid insertion of the tube into the pulmonary system or other inappropriate locations. One of the challenges of feeding tube verification at the bedside is that none of the nonradiographic verification methods identifies incorrect positioning of the feeding tube within the gastrointestinal tract, such as tubes placed in the esophagus or the gastroesophageal junction.22  Administration of formula or medications through a feeding tube with ports positioned above the lower esophageal sphincter (esophageal or gastroesophageal placement) may place the patient at higher risk for aspiration of gastric fluid, medications, and/or formula into the pulmonary system.12,23,24  Because other methods do not allow identification of the exact tube position within the gastrointestinal tract, radiography is considered the gold standard for verification of blindly inserted feeding tubes before administration of formula or medications.11,12  Electromagnetic placement devices have been suggested as a replacement for radiographic confirmation of feeding tube placement at the bedside, although adverse outcomes have been reported, implying that a high level of user expertise may be necessary to obtain consistently positive results.25 

The 2 verification methods used most often by critical care nurses for initial verification of feeding tube placement in our study were observation for signs of respiratory distress and visual observation of aspirate from the feeding tube. These 2 methods are less reliable than capnography and pH methods. Although signs of respiratory distress such as decreased oxygen saturation, coughing, and dyspnea have been reported, pulmonary placement has occurred without any signs of respiratory distress.4  Critical care nurses should also be aware that cuffs from endotracheal and tracheostomy tubes do not prevent pulmonary placement of feeding tubes.3  Visual observation of the color and consistency of gastric aspirate has also been used to verify feeding tube placement. Fluid from gastric placement has been reported as green, tan, off-white and cloudy, or brown or bloody.26  Aspirates from tubes with pulmonary placement are yellow and serous or off-white/tan and mucous.26  In 1 study,26  aspirate from a number of feeding tubes with pulmonary placement resembled the color and consistency of gastric aspirate, and nurses accurately identified tubes with pulmonary placement only 57% of the time.

In our study, capnography and pH measures were infrequently used for initial verification of feeding tube placement, a finding similar to results of another national US study of critical care nurses.2  Although these 2 methods can be performed independently by nurses, barriers that may inhibit use of either technique include the need for additional supplies, equipment, and training.2  Additional barriers to the use of pH methods for ongoing tube verification include the use of formula or medications that lower gastric acid, such as H2 blockers and proton pump inhibitors.2730  Owing to the effects of medications and formula on pH measures, using the pH method to verify tube placement after feeding has been started requires that formula be withheld.30  The optimal length of time that feeding should be suspended for accurate pH measurement was suggested as “more than a few hours” in the practice alert, although in 1 research protocol, pH measures were delayed for only 1 hour after medication administration or formula being stopped.30  Researchers have also reported difficulty obtaining gastric aspirate from feeding tubes, which may pose an additional challenge to pH measurements.29  In 1 study,30  researchers recommended that 30 mL of air be instilled into the feeding tube via a syringe to clear the tube of formula before aspirating fluid.

Feeding tubes misplaced in the pulmonary system do not always result in signs of respiratory distress.

As previously mentioned, methods such as capnography and pH do not allow users to discriminate between different tube positions within the gastrointestinal tract.24,31  These methods are sensitive to differentiating between the pulmonary and gastrointestinal systems,27,32  which may reduce risk of pulmonary placement. For example, a pH less than 5.0 typically indicates gastric placement, and a pH greater than 6.0 indicates intestinal or pulmonary placement.30,3335  Unfortunately, feeding tube placement in the esophagus or gastroesophageal junction cannot be confirmed, making pH and capnography methods inconclusive for initial verification of feeding tube placement.24,31,36 

The location of the feeding tube should be verified every 4 hours once feeding has been established to assess for change in tube position.2,12,17  Methods for ongoing verification may include monitoring the length of the externally marked feeding tube from the exit site (nare or lip)12,37,38  or monitoring gastric residual volumes for changes.17  Nurses are encouraged to inspect the external tube mark at 4-hour intervals to check for a change in length of the external portion of the tube. Although this method is not empirically based, the premise is that an increase in external length of the tube may prompt the nurse to perform additional verification methods such as radiographic confirmation to assess for a change in tube position.2,38  Moreover, radiographic confirmation is recommended any time that improper placement of a feeding tube is suspected.12 

Nurses are encouraged to use evidence-based, peer-reviewed practice alerts.

Only 12% of nurses avoided using auscultation all of the time when verifying feeding tube placement, suggesting that 88% of nurses continued to use auscultation for feeding tube verification (all or some of the time), even though accuracy of this method is disputed.39  Our results are in agreement with other studies that reported auscultation was used by 73% to 93% of critical care nurses to verify initial feeding tube placement.2,40,41  Of the practices examined in our survey, auscultation required the least amount of specialized equipment or supplies, which may be one of the reasons this practice continues to be widely used.2 

It is disconcerting that auscultation continues to be one of the most commonly used methods for feeding tube verification. More than 20 years ago, Metheny et al42  reported that auscultation methods were only 34% accurate, a message that was repeated by Rauen et al.4 . Use of auscultation may compromise patient safety by failure to distinguish feeding tube locations both within and outside of the gastrointestinal tract.11,12,14,17  Nurses should replace auscultation practice with evidence-based methods for feeding tube verification.

Nurses can also play a role in increasing their knowledge of practices for verifying feeding tube location by reviewing AACN’s practice alert, presentation, and audit tool (www.aacn.org). At the unit level, audits are recommended to increase awareness of local practices for verifying feeding tube location so that a practice improvement plan can be implemented if necessary. To support local practices, institutional practice policies should be evidence-based and developed by an interdisciplinary team.44 

On the basis of our findings, we recommend 3 revisions of the practice alert under the headings of Expected Practice and Actions for Nursing Practice. A variety of methods are recommended for initial confirmation of feeding tube location, yet the exact number is not explicitly identified. It would be helpful to confirm the expected number of methods/techniques to be used, by including a statement such as “2 or more.” The current practice alert states that auscultation is unreliable, but it does not include an action statement for nursing practice. Because a majority of the nurses in our sample continue to use auscultation in their practice, a bold action statement should be added, such as “Do not use unreliable methods such as auscultation and water bubbling. Evidence does not support these methods and suggests risk for patient harm if used.” The third recommendation is to modify the language used for radiographic confirmation. Instead of “obtain radiographic confirmation,” a revised statement such as “encourage or recommend radiographic confirmation” would be actionable by all nurses because it is within the scope of practice for a generalist registered nurse. It is important to note that the current practice alert suggests that nurses work with an interdisciplinary team to obtain radiographic confirmation.

Limitations of this study have been previously reported.1 

This study is the first to explore one of the AACN practice alerts in detail to determine how practice recommendations are being followed by critical care nurses. Although the majority of critical care nurses in our sample were aware of the practice alert on verification of feeding tube placement, implementation of the expected clinical practices from this guideline varied. We encourage nurses to become familiar with AACN’s practice alerts. Practice alerts are evidence-based, peer-reviewed clinical practice guidelines that are developed by content experts. Implementing expected practices from this practice alert will bring research evidence to the bedside and minimize risk for patient harm.

The authors thank the critical care nurses who participated in this study. Their assistance was instrumental to the success of this project.

1
Bourgault
AM
,
Heath
J
,
Hooper
V
,
Sole
ML
,
Waller
JL
,
NeSmith
EG
.
Factors influencing critical care nurses’ adoption of the AACN practice alert on verification of feeding tube placement
.
Am J Crit Care
.
2014
;
23
(
2
):
134
144
.
2
Metheny
NA
,
Stewart
BJ
,
Mills
AC
.
Blind insertion of feeding tubes in intensive care units: a national survey
.
Am J Crit Care
.
2012
;
21
(
5
):
352
360
.
3
Sorokin
R
,
Gottlieb
JE
.
Enhancing patient safety during feeding-tube insertion: a review of more than 2,000 insertions
.
JPEN J Parenter Enteral Nutr
.
2006
;
30
(
5
):
440
445
.
4
Metheny
N
,
Dettenmeier
P
,
Hampton
K
,
Wiersema
L
,
Williams
P
.
Detection of inadvertent respiratory placement of small-bore feeding tubes: a report of 10 cases
.
Heart Lung
.
1990
;
19
(
6
):
631
638
.
5
Freeberg
SY
,
Carrigan
TP
,
Culver
DA
,
Guzman
JA
.
Case series: tension pneumothorax complicating narrow-bore enteral feeding tube placement
.
J Intensive Care Med
.
2010
;
25
(
5
):
281
285
.
6
Rollins
H
,
Arnold-Jellis
J
,
Taylor
A
.
How accurate are X-rays to check NG tube positioning?
Nurs Times
2012
;
108
(
42
):
14
16
.
7
Hanna
AS
,
Grindle
CR
,
Patel
AA
,
Rosen
MR
,
Evans
JJ
.
Inadvertent insertion of nasogastric tube into the brain stem and spinal cord after endoscopic skull base surgery
.
Am J Otolaryngol
.
2011
;
33
(
1
):
178
180
.
8
Vahid
B
.
Inadvertent placement of a feeding tube in brainstem and spinal cord
.
Intern Med J
.
2007
;
37
(
8
):
577
578
.
9
Metheny
NA
,
Stewart
BJ
.
Testing feeding tube placement during continuous tube feedings
.
Appl Nurs Res
.
2002
;
15
(
4
):
254
258
.
10
Rassias
AJ
,
Ball
PA
,
Corwin
HL
.
A prospective study of tracheopulmonary complications associated with the placement of narrow-bore enteral feeding tubes
.
Crit Care
.
1998
;
2
(
1
):
25
28
.
11
Itkin
M
,
DeLegge
MH
,
Fang
JC
, et al
.
Multidisciplinary practical guidelines for gastrointestinal access for enteral nutrition and decompression from the Society of Interventional Radiology and American Gastroenterological Association (AGA) Institute, with endorsement by Canadian Interventional Radiological Association (CIRA) and Cardiovascular and Interventional Radiological Society of Europe (CIRSE)
.
Gastroenterology
.
2011
;
141
(
2
):
742
765
.
12
Bankhead
R
,
Boullata
J
,
Brantley
S
, et al
.
Enteral nutrition practice recommendations
.
JPEN J Parenter Enteral Nutr
.
2009
;
33
(
2
):
122
167
.
13
American Association of Critical-Care Nurses (AACN)
.
Verification of Feeding Tube Placement Practice Alert
.
2010
. . Accessed November 12, 2014.
14
Patient safety alert: reducing the harm caused by misplaced nasogastric feeding tubes in adults, children and infants
.
November
25
,
2012
. . Accessed November 12, 2014.
15
Peterson
MH
,
Barnason
S
,
Donnelly
B
, et al
.
Choosing the best evidence to guide clinical practice: application of AACN levels of evidence
.
Crit Care Nurse
.
2014
;
34
(
2
):
58
68
.
16
Harrison
MB
,
Graham
ID
,
van den Hoek
J
,
Dogherty
EJ
,
Carley
ME
,
Angus
V
.
Guideline adaptation and implementation planning: a prospective observational study
.
Implement Sci
.
2013
;
8
(
1
):
49
.
17
American Association of Critical-Care Nurses (AACN)
.
Verification of Feeding Tube Placement Practice Alert
.
2009
. . Accessed November 12, 2014.
18
Rogers
EM
.
Diffusion of Innovations
.
New York, NY
:
Free Press
;
2003
.
19
Brett
JL
.
Use of nursing practice research findings
.
Nurs Res
.
1987
;
36
(
6
):
344
349
.
20
American Association of Critical-Care Nurses (AACN)
.
CCRN Introduction
.
2014
. . Accessed November 12, 2014.
21
American Association of Critical-Care Nurses (AACN)
.
Beacon Award for Excellence
. . Accessed November 12, 2014.
22
Bourgault
AM
,
Halm
MA
.
Feeding tube placement in adults: safe verification method for blindly inserted tubes
.
Am J Crit Care
.
2009
;
18
(
1
):
73
76
.
23
Mizock
BA
.
Risk of aspiration in patients on enteral nutrition: frequency, relevance, relation to pneumonia, risk factors, and strategies for risk reduction
.
Curr Gastroenterol Rep
.
2007
;
9
(
4
):
338
344
.
24
Burns
SM
,
Carpenter
R
,
Blevins
C
, et al
.
Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector
.
Am J Crit Care
.
2006
;
15
(
2
):
188
195
.
25
Metheny
NA
,
Meert
KL
.
Effectiveness of an electromagnetic feeding tube placement device in detecting inadvertent respiratory placement
.
Am J Crit Care
.
2014
;
23
(
3
):
240
248
.
26
Metheny
N
,
Reed
L
,
Berglund
B
,
Wehrle
MA
.
Visual characteristics of aspirates from feeding tubes as a method for predicting tube location
.
Nurs Res
.
1994
;
43
(
5
):
282
287
.
27
Turgay
AS
,
Khorshid
L
.
Effectiveness of the auscultatory and pH methods in predicting feeding tube placement
.
J Clin Nurs
.
2010
;
19
(
11–12
):
1553
1559
.
28
Neumann
MJ
,
Meyer
CT
,
Dutton
JL
,
Smith
R
.
Hold that x-ray: aspirate pH and auscultation prove enteral tube placement
.
J Clin Gastroenterol
.
1995
;
20
(
4
):
293
295
.
29
Conner
TM
,
Carver
D
.
The role of gastric pH testing with small-bore feeding tubes in the intensive care unit
.
Dimens Crit Care Nurs
.
2005
;
24
(
5
):
210
214
.
30
Metheny
N
,
Reed
L
,
Wiersema
L
,
McSweeney
M
,
Wehrle
MA
,
Clark
J
.
Effectiveness of pH measurements in predicting feeding tube placement: an update
.
Nurs Res
.
1993
;
42
(
6
):
324
331
.
31
Stepter
CR
.
Maintaining placement of temporary enteral feeding tubes in adults: a critical appraisal of the evidence
.
Medsurg Nurs
.
2012
;
21
(
2
):
61
102
.
32
Chau
JPC
,
Lo
SHS
,
Thompson
DR
,
Fernandez
R
,
Griffiths
R
.
Use of endtidal carbon dioxide detection to determine correct placement of nasogastric tube: a meta-analysis
.
Int J Nurs Stud
.
2011
;
48
(
4
):
513
521
.
33
Metheny
N
,
Williams
P
,
Wiersema
L
,
Wehrle
MA
,
Eisenberg
P
,
McSweeney
M
.
Effectiveness of pH measurements in predicting feeding tube placement
.
Nurs Res
.
1989
;
38
(
5
):
280
285
.
34
Metheny
NA
,
Stewart
BJ
,
Smith
L
,
Yan
H
,
Diebold
M
,
Clouse
RE
.
pH and concentrations of pepsin and trypsin in feeding tube aspirates as predictors of tube placement
.
JPEN J Parenter Enteral Nutr
.
1997
;
21
(
5
):
279
285
.
35
Metheny
NA
,
Smith
L
,
Stewart
BJ
.
Development of a reliable and valid bedside test for bilirubin and its utility for improving prediction of feeding tube location
.
Nurs Res
.
2000
;
49
(
6
):
302
309
.
36
Araujo-Preza
CE
,
Melhado
ME
,
Gutierrez
FJ
,
Maniatis
T
,
Castellano
MA
.
Use of capnometry to verify feeding tube placement
.
Crit Care Med
.
2002
;
30
(
10
):
2255
2259
.
37
Metheny
NA
,
Schnelker
R
,
McGinnis
J
, et al
.
Indicators of tubesite during feedings
.
J Neurosurg Nurs
.
2005
;
37
(
6
):
320
325
.
38
Metheny
NA
,
Titler
MG
.
Assessing placement of feeding tubes
.
Am J Nurs
.
2001
;
101
(
5
):
36
45
.
39
Kawati
R
,
Rubertsson
S
.
Malpositioning of fine bore feeding tube: a serious complication
.
Acta Anaesthesiol Scand
.
2005
;
49
(
1
):
58
61
.
40
Fulbrook
P
,
Bongers
A
,
Albarran
JW
.
A European survey of enteral nutrition practices and procedures in adult intensive care units
.
J Clin Nurs
.
2007
;
16
(
11
):
2132
2141
.
41
Phillips
NM
,
Endacott
R
.
Medication administration via enteral tubes: a survey of nurses’ practices
.
J Adv Nurs
.
2011
;
67
(
12
):
2586
2592
.
42
Metheny
N
,
McSweeney
M
,
Wehrle
MA
,
Wiersema
L
.
Effectiveness of the auscultatory method in predicting feeding tube location
.
Nurs Res
.
1990
;
39
(
5
):
262
267
.
43
Rauen
CA
,
Chulay
M
,
Bridges
E
,
Vollman
KM
,
Arbour
R
.
Seven evidence-based practice habits: putting some sacred cows out to pasture
.
Crit Care Nurse
.
2008
;
28
(
2
):
98
124
.
44
Melnyk
BM
,
Fineout-Overholt
E
,
Gallagher-Ford
L
,
Stillwell
SB
.
Sustaining evidence-based practice through organizational policies and an innovative model
.
Am J Nurs
.
2011
;
111
(
9
):
57
60
.

Footnotes

To purchase electronic or print reprints, contact the American Association of Critical-Care Nurses, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 899-1712 or (949) 362-2050 (ext 532); fax, (949) 362-2049; e-mail, [email protected].

Financial Disclosures

This study was supported by a grant from Sigma Theta Tau, Beta Omicron Chapter.

eLetters

Now that you’ve read the article, create or contribute to an online discussion about this topic using eLetters. Just visit www.ccnonline.org and select the article you want to comment on. In the full-text or PDF view of the article, click “Responses” in the middle column and then “Submit a response.”

dOtmore

To learn more about caring for patients with feeding tubes, read “Effectiveness of an Electromagnetic Feeding Tube Placement Device in Detecting Inadvertent Respiratory Placement” by Metheny and Meert in the American Journal of Critical Care, May 2014;23:240–248. Available at www.ajcconline.org.